XLT SERIES OWNER’S MANUALThe Coolest Thing In Wine StorageFOR:XLT 1600XLT 3000XLT 4200XLT 6000XLT 8000
Page 8 XLT 112910Cutting the Hole for the WhisperKOOL Unit Tools Needed Sizing the Unit to the Room • Using a level and a pencil, mark a horizontal li
Page 9 XLT 112910• Once the horizontal lines have been cut, make vertical cuts using the inside edge of the studs as a guide. Once you have made both
Page 10 XLT 112910Electrical NeedsThe WhisperKOOL System requires a dedicated 110-volt 20-amp circuit. The unit draws a large amount of amps at initia
Page 11 XLT 112910Carefully remove your WhisperKOOL unit from the box. Do not destroy your packing material, as it provides the only safe means
Page 12 XLT 112910Placement of UnitSlide the unit from the outside wall into your wine cellar with the outer flange flush to the outside wall. Secure
Page 13 XLT 112910Drain lineT-FittingWRONG: Drainline is under water.USING THE WHISPERKOOL SYSTEM®FRONTREAROFFPOWERLocation of control switchesSwitche
Page 14 XLT 112910LIQUID MEASURING THERMOSTAT SYSTEMRoom-temperature WaterFill an empty bottle with room-temperature water; then insert the probe.All
Page 15 XLT 112910Operating Instructions for WhisperKOOL PDT JR. ThermostatIndicatorsThere are three colored lights on the left side of the thermostat
Page 16 XLT 1129101. Wine Temperature Indicator: A red LED bar will light up when the thermostat is reading the liquid temperature in the bottle via t
Page 17 XLT 112910NORMAL OPERATIONWhisperKOOL systems are designed to maintain both temperature and humidity. Once the system is installed and the tem
Copyright © 2011. WhisperKOOL Wine Cellars. All rights reserved. This manual, the product design, and the design concepts are copyrighted by WhisperKO
Page 18 XLT 112910DUCTINGA WhisperKOOL XLT ducting kit is available for purchase. The kit allows the warm air to exhaust to several places such as an
Page 19 XLT 112910TROUBLESHOOTING GUIDETry this first!Clean off any accumulated dust, lint, or other debris from the front and rear intake grills. Thi
Page 20 XLT 112910VentilationProper ventilation of the WhisperKOOL unit is one of the most important and often overlooked issues associated with the
Page 21 XLT 112910Unit MountingMounting the unit in the cellar has a significant impact on the unit’s ability to cool the air in the room. A l
Page 22 XLT 112910CondensationWater Leaking, FrontThe WhisperKOOL product is designed to dissipate excessive moisture by collecting it in the compress
Page 23 XLT 112910Repairing Units - Removing RivetsOnly a certified HVAC tech should work on the units. We do not want owners opening the units for th
Page 24 XLT 112910Yes NoTROUBLESHOOTING CHECKLISTPlease ll out this checklist to help identify the issue or problem with the performance of the coo
Page 25 XLT 112910Yes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoAll units come with a drain line for
Page 26 XLT 112910The purpose of this test is to evaluate whether or not your cooling unit is operating correctly by mea-suring the temperatures of bo
Page 27 XLT 112910THIRD TEMPERATURE TEST:10. Once the unit has run for 24 hours, perform the third temperature test.11. Record information and calcula
Introduction ...2Receiving and Insp
Page 28 XLT 112910ConclusionsAfter completing the temperature dierential test, determine if the unit is not cooling at all or if it is not cooling en
Page 29 XLT 112910WhisperKOOL Customer Service is available Monday through Friday from 8:00 a.m. to 4:00 p.m. Pacific Standard Time.Please make sure t
Page 30 XLT 112910INSTALLATION TERMS AND CONDITIONS WhisperKOOL Cooling SystemWHISPERKOOL PRODUCT BASE TERMSWhisperKOOL Corporation (“WhisperKOOL”) is
Page 31 XLT 112910C Product Warranty Limitations and Exclusions. (1) This limited warranty does not cover cosmetic damage caused during installati
Page 32 XLT 112910 4. MAINTENANCE REQUIREMENTS It is the End User’s responsibility to clean o any accumulated dust, lint, or other debris from the fr
Page 33 XLT 1129109. Questions or Additional InformationIf you have any questions regarding these Terms and Conditions or wish to obtain additional in
NOTES
Page 2 XLT 112910Thank you for purchasing the WhisperKOOL® wine cellar temperature and humidity maintenance system.Please take the time to read
Page 3 XLT 112910Customer Warranty Registration PLEASE COMPLETE AND RETURN THE REGISTRATION/WARRANTY CARD UPON RECEIPT OF THE UNIT. By completing the
Page 4 XLT 112910QUICK START GUIDE This guide is meant to serve as a quick reference for installation of the WhisperKOOL unit. The remainder of this
Page 5 XLT 112910The performance and life of your WhisperKOOL System are contingent upon the steps you take in preparing the wine cellar.IT IS HIGHLY
Page 6 XLT 112910Front of WhisperKOOLWine CellarExhaust RoomIntakeExhaustUnobstructed AirflowUnobstructed airflow to and from the unit is a critical f
Page 7 XLT 112910Ventilation The necessity of dissipating heat away from the unit is critical to the unit’s performance and cannot be overstated. As t